Synthes distal fibula inventory

For the distal femur, accurate anteroposterior and lateral X-rays centered on the joint are neces.

LCP™ Anterolateral Distal Tibia Plates. The head of the plate features four locking holes that accept locking screws ø 3.5 mm, cortex screws ø 2.7 mm / ø 3.5 mm and cancellous bone screws ø 4.0 mm. The combi-holes in the plate shaft accept locking screws ø 3.5 mm, cortex screws ø 3.5 mm and cancellous bone screws ø 4.0 mm.(1) Background: As age in western populations is rising, so too are fractures, e.g., of the distal fibula. The aim of this study was to find out whether a novel, minimally invasive intramedullary osteosynthesis technique for the treatment of distal fibula fractures in elderly patients results in not only a reduction of postoperative complications, but also a shorter hospitalization time, an ...4.5 mm LCP® Proximal Tibia Plates - synthes.vo.llnwd.netInventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS33 Confirm nail length and diameter Instrument 03.010.021 Radiographic Ruler for Tibial Nails, length 450 mm The required nail length must be determined after reduction of the lower leg fracture. Position the C-arm for an AP view of the distal tibia. With long forceps, hold the ruler along the leg, parallel to and at the same level as the tibia.Jun 3, 2013 · Fig 7 VA-LCP Lateral Distal Fibula Plate with six 2.7 mm VA holes in the head in Stainless Steel VA-LCP Lateral Distal Fibula Plate in Titanium The Variable Angle LCP Ankle Trauma system also comprises a compression and distraction system, which is an important tool for reduction (i.e. bringing a fibula out to length) or compression of a ...Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.The VariAx 2 Distal Radius and VariAx 2 Distal Ulna Plating Systems provides you with a comprehensive range of anatomic plating options that work with a common instrument and screw platform. Plates utilize SmartLock technology which permits polyaxial screw placement. You can angle locking screws up to 15˚in each direction for a total range of ...Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.In our study, the fibula nail was tested for the first time, biomechanically fixed with two syndesmotic screws in addition to double distal locking, as required by the system. However, unlike the plate, these two screws were an integral part of the fibula nail system and inserted regardless of the stage of syndesmosis injury.The RFN-ADVANCED™ System is a retrograde femoral nailing system designed to improve fixation for distal femur fractures 1. As part of the Advanced Nailing System, it is designed to address simple to complex trauma cases 2 with increased fixation and stability. 1,3. Product Specifications. How to Use This Product.Inventory Control Form Small Fragment Locking Compression Plate (LCP™) System 204.848 3.5 mm Locking Screws, self-tapping, with StarDrive™ Recess Length 202.830 30 mm 202.832202.812 32 mm 202.834 34 mm 202.816 202.836 36 mm 202.818 202.838 38 mm 202.840202.820 40 mm 202.845 45 mm 202.850 50 mm 202.826 202.855 55 mm Length 212.113 34 mm 212. ...synthes.vo.llnwd.netIndications The Synthes LCP Low Bend Medial Distal Tibia Plates are intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal tibia, as a part of the Synthes Small Fragment LCP System. Synthes 5. Open the catalog to page 7. Complete the preoperative radiographic assessment and prepare the preoperative plan.02.112.138 - SYNTHES 2.7MM/3.5MM LCP LATERAL DISTAL FIBULA PLATE, STAINLESS STEEL, 86MM, RIGHT. SYNTHES 02.112.138 $ 395.00 $ 395.00 $ 395.00. Add to wishlist. Get notification as soon as the product is available again. ...The RFN-ADVANCED™ System is a retrograde femoral nailing system designed to improve fixation for distal femur fractures 1. As part of the Advanced Nailing System, it is designed to address simple to complex trauma cases 2 with increased fixation and stability. 1,3. Product Specifications. How to Use This Product.Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.pull traction at 30° angle over triangle for reduction. Reaming. ream 1.5mm above size of final nail. Nail Insertion. insert nail over guidewire. Interlocking Screws. targeting guide to place distal interlocking screws first. check femoral neck, get perfect circles of proximal interlocking screws and insert.The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.Our LCP™ Hook Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features pointed hooks to aid in plate placement and holes for both lag screws and locking screws. Product Specifications. How to Use This Product.With its patented polyaxial locking technology, VariAx brings something new to surgeons: convenience. The adaptable design allows for modularity and variable angles, meaning screw positioning can be based on the patient at hand, not a plate’s pre-existing design. Dr. Panchbhavi demonstrates a Distal Fibula Fracture procedure using the VariAx ...Move the image intensifi er to the distal femur, place the proximal end of the radiographic ruler at the skin mark, and take an AP image of the distal femur. Verify fracture reduction. Read nail length directly from the ruler image, selecting the measurement that places the distal end of the nail at, or just proximal to, the physeal scar, or theThe information that must be reported on a synforms distal fibula inventory includes the patient's name and medical record number, date of the inventory, the size of the inventory, the type of synform used (e.g. standard, reverse, hybrid), the angle of the distal fibula, the location of the tibial tuberosity, the position of the fibula relative to the tibia, the presence or absence of any ...The LCP Anterolateral Distal Tibia Plate 3.5 is indicated for: – Extra-articular and simple intra-articular distal tibia fractures – Distal tibia fracture, percutaneous or reducible by limited arthrotomy – Distal tibia fracture extending into the diaphyseal area Synthes 5 0x6.000.333_AB.qxp:0X6.000.333_AB 04.12.2008 14:57 Uhr Seite 5LCP Anterolateral Distal Tibia Plate 3.5 • Surgical Technique 7 2. Reduce articular surface Optional instrument 394.350 Large Distractor 395.490 Medium Distractor Approach A longitudinal and straight incision should be centered at the ankle joint, parallel to the fourth metatarsal distally, and between the tibia and fibula proximally. ProximalThe 2.7mm VA LCP™ Clavicle Hook Plate System provides solutions for lateral clavicle fractures with associated acromioclavicular and coracoclavicular ligament injuries and isolated ligamentous injuries. The Clavicle Hook Plates have enhanced hook depths and angulations based on an extensive analysis of shoulder morphology. 1,2 *.02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.DCPTM and LC-DCPTM Systems - synthes.vo.llnwd.netment only. The most distal bolt must be left in the distal fragment until the extractor head is locked onto the distal nail fragment. (FIG. 1) 1 Expose nail Expose the proximal end of the nail. Remove the nail end cap, if present. If no end cap was used, use a sharp hook to clean out the connecting thread in the proximal end of the nail. 2Anterolateral Distal Tibia Plate • Seven hole distal cluster is anatomically contoured to capture distal fragments, while proximal plate curves to mate with the anterior surface of the tibia Available in 4 hole, 6 hole, 8 hole, 10 hole, 12 hole, 14 hole, 16 hole, and 18 hole right and left side specific plates Medial Distal Tibia PlateWith posterior plating becoming a more common means of treating distal tibia and fibula fractures over an anterior to posterior approach, Paragon 28® wanted to provide surgeons with a complete offering to address these fractures in the manner they prefer. With our already robust Ankle Fracture Plating System, we now also include a full ...The FIBULINK Syndesmosis Repair System Implants are offered in stainless steel or titanium, and are provided in sterile, single use kits. It is compatible with all DePuy Synthes distal fibula plates and any plate hole that accepts a 4 mm non-locking cortex screw.7. “The acquisition of Akros and subsequent launch of this key technology ...DePuy Synthes Stainless Steel Right LCP Lateral Distal Fibula Plate, 2.7/3.5 mm Size, 73 mm Length, 3 Holes DEPUY SYNTHES: 02.112.136 The store will not work correctly in the case when cookies are disabled.Synthes VA Ankle Trauma is used for ankle fixation in adults and children (12-21) whose growth plates have united, especially in osteopenic bone. The plates are a component of the DePuy Synthes Variable Angle Locking Compression (VA LCP) System, which combines traditional plating methods with technology for variable angle locking screws. The plates are in stainless steel and have an ...4 DePuy Synthes 3.7 mm Cannulated Locking and Conical Screws Surgical Technique Indications For fixation of fractures, osteotomies, and nonunions of the clavicle, scapula, olecranon, humerus, radius, pelvis, tibia, and fibula, particularly in osteopenic bone.%PDF-1.6 %âãÏÓ 1291 0 obj > endobj 1345 0 obj >/Filter/FlateDecode/ID[3C1E0D985D467D43BC863940EBE6191A>]/Index[1291 116]/Info 1290 0 R/Length 207/Prev 489666/Root ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010• Distal Fixation 81 Alternative Surgical Technique 83 • Preoperative Planning 83 • Patient Positioning and Approach 84 • Guide Wire Insertion 85 LCP Pediatric Condylar Plate 90°, 3.5 and 5.0 88 • Preoperative Planning 88 • Patient Positioning and Approach 90 • Guide Wire Insertion 91 • Osteotomy 97 • Distal Fixation 99DePuy Synthes is a global leader in medical devices for foot and ankle procedures. Our foot and ankle portfolio is the result of working with healthcare professionals around the globe to develop solutions tailored to the needs of both patients and surgeons. We offer comprehensive solutions for foot and ankle reconstruction, elective and trauma ...Our LCP™ Hook Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plate features pointed hooks to aid in plate placement and holes for both lag screws and locking screws. Product Specifications. How to Use This Product.VariAx Distal Fibula Locking Plate System The VariAx Distal Lateral Plate is intended for use in internal fixation of the distal fibula. The VariAx Fibula Straight Plates are intended for use in internal fixation of the distal fibula. Indications • Obesity. An overweight or obese patient can produce loads on the implant that can lead to failure01. Edit your synthes compact ankle inventory online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a signature pad. 03. Share your form with others. Send va ankle inventory via email, link, or fax.Plate features - Head of plate is low profile for minimal prominence on medial malleolus - 3.5 mm cortex and 4.0 mm cancellous bone screws sit flush with plate in the nonlocking portion of distal combiholes to minimize screw prominence - Rounded edges to minimize soft tissue irritation - Limited-contact shaft profile - Available in stainless steel or titanium Combi-holes in the shaft ...Android: Milo takes price comparison a step further by not only showing you the local prices for products you're interested in but giving you real-time inventory reports for local ...APTUS® Wrist. APTUS. ®. Wrist. The wrist is a multi-articular joint. It consists of the carpus, distal ulna and distal radius. Fractures of the distal radius are the most common fractures in the human body. In recent years, great changes have taken place both in the treatment options of the distal radius and the patient demands which have ...The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolateral, medial, anterior, and posterior tibia plates; 2.7 mm straight plates; and two styles of posterolateral fibula plates• Particular attention was placed on maintaining a low-profile design by optimizing contour and fit to minimize soft-tissue irritation• The ...The FibuLock fibular nail is a cutting-edge, biologically friendly treatment for ankle fractures. It is inserted into the fibula through a small incision and acts like an internal splint to stabilize the fracture during healing. This minimally invasive technique may reduce wound complications often associated with standard open reduction internal fixation (ORIF) …The distal Schanz screw should be placed parallel to the axis of the knee joint, in the posterior half of the condyle, approximately 2 cm to 3 cm from the articular surface and inserted laterally or anterolaterally. Note: For certain plating techniques, it may be necessary to insert the distal Schanz screw medially or anteromedially. Synthes 7Objectives: To document the high failure rate of a specific implant: the Synthes Variable Angle (VA) Locking Distal Femur Plate. Design: Retrospective. Setting: Urban University Level I Trauma Center. Patient/participants: All distal femur fractures (OTA/AO 33-A, B, C) treated from March 2011 through August 2013 were reviewed from our institutional orthopaedic trauma registry.With its patented polyaxial locking technology, VariAx brings something new to surgeons: convenience. The adaptable design allows for modularity and variable angles, meaning screw positioning can be based on the patient at hand, not a plate's pre-existing design. Dr. Panchbhavi demonstrates a Distal Fibula Fracture procedure using the VariAx ...

Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 …The LCP™ Pilon Plate is part of the locking compression plate system and was designed with the following key features: Combi holes that combine a dynamic compression unit with a locking screw hole. Shaft holes that accept 3.5 mm locking screws, 3.5 mm cortex screws, and 4.0 mm cancellous bone screws. A distal portion and arms that may be ...01. Edit your synthes compact ankle inventory online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a signature pad. 03. Share your form with others. Send va ankle inventory via email, link, or fax.Clinical Resources. Surgical Technique Guide. Instructions for Use. -. The 2.4mm LCP Distal Radius System is part of the Locking Compression Plate System that merges locking screw technology with conventional plating techniques.Inventory Control Form Distal Radius Fixator Kirschner Wires with trocar point (10/pkg.) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Fixation Material Patient Information: Distal Radius Fixators, sterile J7013-C 9/12 Self-Drilling Schanz Screws (stainless steel)LCP Anterolateral Distal Tibia Plate 3.5 LCP Clavicle Hook Plate LCP Compact Foot / Compact Hand LCP Compact Hand LCP Compact Hand 1.5 LCP Condylar Plate 4.5/5.0 LCP DF and PLT LCP DHHS LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate
The distal, lateral femoral locking plate (Synthes Tomofix, West Chester, PA) is then positioned on .

The VariAx Fibula Locking Plate System represents a new generation of implant technology. Pre-contoured periarticular plate design with type II anodization. Low-profile plate design and reduced screw head prominence. K-wire holes in plate. Wide range of 3.5mm locking and non-locking screw lengths. Contact.2.7 MM VA LCP™ CLAVICLE System. Product Codes: 02.112.610, 02.112.611, 02.112.612... View More. PRODUCT CODES. DESCRIPTION. Designed based on an analysis of clavicle CT scans to enhance plate-to-bone fit on a broad range of patients 1 and to treat lateral, shaft and medial fractures for small, medium and large clavicles.Abstract. Objective The literature entails various intramedullary and extramedullary methods for distal fibula fracture fixation; with no consensus yet over the ideal method of fixation. We have retrospectively analyzed the results of using a twisted and contoured 3.5 mm locking compression plate (LCP) as a posterior buttress plate.The LCP Anterolateral Distal Tibia Plate 3.5 is indicated for: – Extra-articular and simple intra-articular distal tibia fractures – Distal tibia fracture, percutaneous or reducible by limited arthrotomy – Distal tibia fracture extending into the diaphyseal area Synthes 5 0x6.000.333_AB.qxp:0X6.000.333_AB 04.12.2008 14:57 Uhr Seite 5In our study, the fibula nail was tested for the first time, biomechanically fixed with two syndesmotic screws in addition to double distal locking, as required by the system. However, unlike the plate, these two screws were an integral part of the fibula nail system and inserted regardless of the stage of syndesmosis injury.Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42-60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.synthes.vo.llnwd.net• Eight distal locking holes accept 2.7 mm cortex, 3.5 mm locking, 3.5 mm cortex, or 4.0 mm cancellous bone screws • Proximal and distal holes for 1.6 mm or 2.0 mm Kirschner wires • 316L stainless steel or titanium • Locking holes in distal region are parallel to the joint • Elongated hole in shaft aids in initial plate positioningLCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP Extra-articular Distal Humerus Plate LCP Hook Plate 3.5 LCP Locking Compression Plate LCP Low Bend Medial Distal Tibia Plates 3.5 mm LCP Medial Proximal Tibial Plate 3.5This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.Synthes 02.112.142 LCP Lateral Distal Fibula Plate 2.7/3.5 x 112mm 6 Holes - Right NEW IN PACKAGE . Synthes 02.112.142 LCP Lateral Distal Fibula Plate 2.7/3.5 x 112mm 6 Holes - Right NEW IN PACKAGE ... We also purchase any surplus inventory or unused equipment and instrumentation. Exchange and consignment programs are also …Three types of distal fibula plates are available with contours to match patient anatomy and minimize the need for intraoperative bending. Low Profile Design. Low profile plates are designed for minimal screw prominence to help reduce soft tissue irritation. Unique Instruments.DePuy Synthes, part of the Johnson & Johnson Family of Companies, is a global leader in medical devices used to treat orthopaedic trauma. The company's fixation products, including screws, plates, nails and other implants, are used to treat fractures and deformities related to the extremities and provide one of the most comprehensive portfolios of orthopaedic solutions in the world.System. PHILOS ® System is an anatomical LCP plating system for proximal humerus fracture fixation. It includes the PHILOS ® Percutaneous Aiming System, for a less invasive transdeltoid approach. Unfortunately, we can't detect an electronic copy of the Instructions for Use (IFU) you are seeking. You can locate the IFU for this product by:Synthes has established the performance and safety of the Universal Small Frag-ment System, and that they represent state of the art medical devices for surgical treatment and stabilization of fractures in various anatomical regions when used in conjunction with plates implants and according to their instructions for use and labeling.Distal hereditary motor neuropathy, type II is a progressive disorder that affects nerve cells in the spinal cord. Explore symptoms, inheritance, genetics of this condition. Distal...Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4/2.7, Extra-long Variable Angle LCP Volar Rim Distal Radius Plate 2.4 Variable Angle Locking Hand System Please read these instructions for use, the Synthes brochure"Important Informa-tion" carefully before use.DEPUY SYNTHES: 02.112.153. LCP Lateral Distal Fibula Plate, 2.7/3.5 mm Size, 177 mm Length, Stainless Steel, Fixed Angle, 11-Hole, Left Version, Non-Sterile, Single-Use, For 2.7/3.5 mm LCP Lateral Distal Fibula Plate Instrument and Implant Set. The 2.7 mm/3.5 mm LCP distal fibula plates are part of the DePuy Synthes locking compression plate ...Note: If the bending/cutting pliers are used on a plate with preassemble drill sleeves, the drill sleeves must first be removed from the plate. 8 Synthes LCP Compact Hand 1.5 Technique Guide. Open the catalog to page 10. Contour plate with thread 347.901 Pliers, flat-nosed, pointed, If necessary, contour the plate to suit anatomical conditions.LCP Dia-Meta Volar Distal Radius Plates LCP Distal Fibula Plates LCP Distal Humerus Plates LCP Distal Radius System 2.4 LCP Distal Tibia Plate LCP Distal Ulna Plate LCP …Quickly produce a Synthes Large Frag Inventory without needing to involve specialists. There are already over 3 million users making the most of our unique collection of legal forms. ... humerus, radius, ulna, pelvis, distal tibia, and fibula, particularly in osteopenic bone. What size is a mini frag? The Mini Fragment System (or "Mini Frag ...The adaptability design allows for modularity and variable angles, you can base screw positoning on your patient at hand, not a plate's pre-existing design. Compression and locking in one step. Patented SmartLock polyaxial locking technology 1. Seven new indication specific plates. Locking screws can be angled ±15° for a total range of 30°.Evan Goldberg of Oracle NetSuite discusses the new challenges of Just in Time inventory. About this time every year I look forward to heading to Oracle NetSuite’s annual user confe...Keeping track of your possessions and cargo during a move can be difficult. We’re here to help with our comprehensive guide to home inventory lists. Expert Advice On Improving Your...Inventory ontrol orm 3 3 Miscellaneous Implants Instruments Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. 3.5LCPPROXTIBICF001 07/22 219.98 Washer, 7.0 mm 292.20 2.0 mm K-wire, 150 mm, 10/pkg.